Power Standby Switch Disable Jumper Locations; Power Tray J7 Jumper Configurations - Intel NetStructure ZT 5085 12U Manual

Redundant host packet switched platform
Table of Contents

Advertisement

Getting Started
Warning:
It is critical that both power trays have the same J7 jumper configuration. If the power trays are
configured differently, the power standby switch controls only one power tray. This can result in an
improper cooling scenario.
Figure 15. Power Standby Switch Disable Jumper Locations
Table 3
lists the configuration choices for the J7 jumpers.
Table 3.

Power Tray J7 Jumper Configurations

Power Tray 1 J7
Jumper
Installed
Removed
Installed
Removed
32
Front
Power Tray 2 J7
Jumper
+
Installed
=
+
Removed
=
+
Removed
=
+
Installed
=
Switch Bypass Jumper
Power Standby
Switch
Enabled
Disabled
Invalid
Invalid
J7 Power Standby
Technical Product Specification