3.4.4 Attach the Coil Pivot

a.
Required Tools:
Flat tip screw driver
b.
To attach the coil pivot:
Attach the O-ring to the coil. The O ring needs to be clean and positioned in the grove
around the cable entry point of the coil. Do not grease the O ring.
The coil cable is attached to the coil and sealed (waterproof) it is only possible to replace
the coil cable by replacing the entire coil (with cable). The coil cable has two windings
(spirals) closest to the coil, turns 90 degrees then five windings of cable(inside the coil
pivot).
It is important to correctly align the coil cable into the coil pivot when assembling with five
(5) windings located within the pivot with the Pin Coil Pivot passing through the centre.
Carefully check the inside of the Pivot Coil Yoke for any corners or edges that could damage
the O ring when the parts are pressed together, remove the Thumb Screw (Screw Thumb
Nylon 1/4BSW) and Screw (Nylon M6x27) from the Pivot Coil Yoke.
O ring
Figure 57: O-Ring and Coil Cable