Insert a flat tip screwdriver into the slot underneath the cap shaft and lift and remove the
cap shaft. Figure 52.
Slide the coil out and off the lower shaft, exposing the coil cable.
Push the coil cable connector into the shaft hinge whilst gently pulling the coil cable out
of the end of the lower shaft, as shown in Figure 53. Once the coil connector has passed
through the shaft hinge it should slide out easily from the shafts. Do not force the coil
cable or coil connector.
b.
The coil can now be removed or replaced as required. To fit the coil to the detector refer
to section
3.4.6 - Fitting the

3.4.3 Coil Pivot.

The coil pivot is a line replaceable unit and Figure 55 illustrates the major parts. Each part
a.
of the coil pivot can be ordered individually or as a 3004-0045 Coil Pivot Kit, which includes all
parts shown in Table 3
Figure 53: Sliding the Coil Off the Shaft
Coil.
Figure 54: Coil Assembly