Minelab MF5 Service Manual page 23

Metal mine detector
Hide thumbs Also See for MF5:
Table of Contents

Advertisement

_________________________________________________________________________________________________________________
Ease the two halves of the detector together. Align the detector chassis right side with the
locating pins either side of the shaft hinge.
Check the Latch Assembly and Spring Latch Hinge are in place and connected.
Once the two sides of the detector are together check the handle, shafts and armrest slide
are correctly fitted. Carefully hold the detector together whilst turning the detector over
onto its right side.
Check the coil cable is not trapped within the shaft hinge.
Attach the Cover Cable.
Insert the four (4) screws (two M4x20mm and two x M4x35mm) but do not fully tighten at
this point.
With the detector loosely held together check the handle slides up and down correctly.
Check the armrest slide also moves freely along the Rod Handle Slide.
Check the Battery Lid moves in and out and ensure the Battery Lid is closed.
Figure 20: Coil Cable Position in Hinge
Figure 21: Insert Four Screws
23
MF5 Service Manual
Coil Cable
Must Not be
above these
screw bosses