3.5.1 Replacing a Camlock

3004-0047 Camlock kit is available as a spare part and includes the following items.
Item
1
2
3
4
a.
Required Tools:
Pin Punch 3mm or Hex key driver (allen key) 3mm
b.
Camlock replacement can be completed as follows:
Fully open the Camlock Lever then using a pin punch and hammer drive the Pin Camlock
Lever out.
Figure 69: Camlock Kit
MRN
Description
3004-0047
Camlock Kit
4308-0014
Pin Camlock Lever
8008-0062
Pressure Block Camlock
8008-0061
Camlock Lever
Table 6: Camlock Kit.