_________________________________________________________________________________________________________________
Connect the flat ribbon cables from the Switch Sensitivity and the User Interface to the
connectors on the Main PCB. First open the connector locking bail (slide out) then firmly
insert the ribbon cable then close the connector locking bail.
Cable to Sensitivity
Switch
Figure 39: Connect User Interface and Switch Sensitivity ribbon cables.
Connect the Coil Transmitter Connector to the Main PCB. Screw the Coil Transmitter
Connector to the Main PCB using M2x5mm screw (31-22005-980). Apply a small amount
of threadlocker (Loctite 222) to the thread of the M2x5mm screw.
Cable to User
Interface (Keypad)
35
Open Locking bail
Connect cable
Locked