Insert the Switch Sensitivity into the detector body; attach the lock washer and 10mm nut.
Attach the Switch knob then the spring followed by the bush and screw to the control
switch. The Screw M3x6 should have a small amount of threadlocker (loctite 222) applied
to the thread of the screw before insertion.
Check the Switch Sensitivity moves through the arc of movement with end stops.
Identify the connector on the Main PCB for the Switch Sensitivity. Open the connector
locking bail (slide out).
Insert the ribbon cable into the connector on the Main PCB then close the locking bail on
the connector.
f.
Reassemble the detector by closing the detector body as described in Section
Detector Chassis