Minelab MF5 Service Manual page 22

Metal mine detector
Hide thumbs Also See for MF5:
Table of Contents

Advertisement

MF5 Service Manual
_________________________________________________________________________________________________________________
Ensure the battery lid is closed.
Check the Seal Chassis (O-ring) in the detector body is clean, lightly greased and correctly
positioned.
Connect the speaker to the PCB. Check all other connectors and cables are connected.
Check all internal cables and wires are correctly positioned and will not be trapped.
The coil cable must be located within the shaft hinge so that it is not trapped or damaged
when the halves of the detector body are fitted together. In particular, the coil cable must
not be positioned above the screw bosses of the hinge.
Speaker Connector
Figure 19: Connect the Speaker.
22
Speaker

Advertisement

Table of Contents
loading

Table of Contents