Technical Data; Application; Function And System Design; Input - Endress+Hauser HART Proline Promass E 200 Operating Instructions Manual

Coriolis mass flow measuring system
Hide thumbs Also See for HART Proline Promass E 200:
Table of Contents

Advertisement

Proline Promass E 200 HART
Measuring principle
Measuring system
Measured variable
Measuring range
Endress+Hauser
17

Technical data

17.1

Application

The measuring device is suitable for flow measurement of liquids and gases only. Depending on the
version ordered, the measuring device can also measure potentially explosive, flammable, poisonous
and oxidizing fluids.
To ensure that the device remains in proper operating condition for its service life, use the measuring
device only for fluids against which the process-wetted materials are adequately resistant.
17.2

Function and system design

Mass flow measurement based on the Coriolis measuring principle
The device consists of a transmitter and a sensor. One device version is available:
Compact version: transmitter and sensor form a mechanical unit.
For information on the structure of the device (® ä 10)
17.3

Input

Measured process variables
• Mass flow
• Density
• Temperature
Calculated process variables
• Volume flow
• Corrected volume flow
• Reference density
Measuring ranges for liquids
DN
[mm]
8
15
25
40
50
Measuring ranges for gases
The full scale values depend on the density of the gas and can be calculated with the formula below:
× r
: x
g
= g
max(G)
max(F)
G
Measuring range full scale values g
[in]
[kg/h]
3/8
0 to 2 000
½
0 to 6 500
1
0 to 18 000
1 ½
0 to 45 000
2
0 to 70 000
Technical data
to g
min(F)
max(F)
[lb/min]
0 to 73.5
0 to 238
0 to 660
0 to 1 650
0 to 2 570
95