Endress+Hauser HART Proline Promass E 200 Operating Instructions Manual page 33

Coriolis mass flow measuring system
Hide thumbs Also See for HART Proline Promass E 200:
Table of Contents

Advertisement

Proline Promass E 200 HART
Endress+Hauser
Display area
In the display area, each measured value is prefaced by certain symbol types for further description:
Measured value type
¯
Example
Measured value types
Mass flow
A0013710
• Volume flow
• Corrected volume flow
A0013711
• Density
• Reference density
A0013946
Measurement channel numbers
The measurement channel number is displayed only if more than one channel is present for the same measured variable
type (e.g. Totalizer 1 to 3).
Measurement channel 1
A0013948
Measurement channel 2
A0013949
Symbols for event level
The symbol for event level pertains to a diagnostic event that is relevant to the displayed process variable.
For more information about the symbols, refer to the "Status area" section (® ä 32).
The number and display of the measured values can be configured via the parameter Display
format.
Navigation path: Display/operat. ® Display ® Display format
Operating elements
Key
Meaning
Enter key
• Pressing the key briefly opens the operating menu.
• Pressing the key for 2 s opens the context menu.
A0013952
Minus/Enter key combination (press and hold down the keys simultaneously)
+
Reduces the contrast (brighter setting).
A0013953
Plus/Enter key combination (press and hold down the keys simultaneously)
+
Increases the contrast (darker setting).
A0013954
Minus/Plus/Enter key combination (press and hold down the keys simultaneously)
+
+
Enables or disables the keypad lock.
A0013955
Measurement channel number
¯
A0013945
Operation options
Symbol for event level
¯
A0013948
Appears only if a diagnostic
event is present for this process
variable.
Temperature
A0013947
Totalizer
The measurement channel
number indicates which of the
A0013943
three totalizers is displayed.
Current output
The measurement channel
number indicates which of the
two current outputs is
A0013945
displayed.
Measurement channel 3
A0013950
Measurement channel 4
A0013951
A0013962
33