10.5.4

Configuring the totalizer

You can configure each totalizer in the three submenus Totalizer 1-3.
Navigation path
"Setup" menu ® Advanced setup ® Totalizer 1
"Setup" menu ® Advanced setup ® Totalizer 2
"Setup" menu ® Advanced setup ® Totalizer 3
Structure of the submenu
Totalizer 1-3
Parameter overview with brief description
Parameters
Prerequisite
Assign process
-
variable
Unit
One of the following options is
selected in the Assign process
variable parameter:
• Mass flow
• Volume flow
• Corrected volume flow
Operation mode
One of the following options is
totalizer 1-3
selected in the Assign process
variable parameter:
• Mass flow
• Volume flow
• Corrected volume flow
Failure mode
One of the following options is
selected in the Assign process
variable parameter:
• Mass flow
• Volume flow
• Corrected volume flow
®
Assign process variable
Unit
Operating mode totalizer 1-3
Failure mode
Description
Select the process
variable for totalizer.
Result
The selection
determines the
choose list of the
Unit parameter.
Select the process
variable of the
totalizer.
Define how the
totalizer totalizes
the flow.
Define how the
totalizer behaves in
an alarm condition.
Commissioning
Selection/
Factory setting
User entry
• Off
Mass flow
• Mass flow
• Volume flow
• Corrected
volume flow
Unit choose list
Country-dependent:
• kg
• lb
• Net flow total
Net flow total
• Forward flow
total
• Reverse flow total
• Stop
Stop
• Actual value
• Last valid value
69