5.5. Equipment configuration

Once the unit has been mounted in its final position and has been solidly secured, ensure that the inverter is properly
set up.
The units always come with factory settings, but when one of the inverters of the units is replaced or repositioned,
the inverter in question must be set up.
Care must be taken to ensure the equipment is not live when accessing its interior.

5.5.1. CAN number setting of an electronic block

Note that in case of inverter change, the inverters come with default factory settings.
Once the unit is properly wired and before connecting it to the network and the PV array:
1.
Press the emergency stop button.
2.
Disconnect optical fibre cable from the inverter to be replaced.
3.
Open Q4 circuit breaker on the power module controlling the inverter.
4.
Connect DC supply. Alarm 1143 will be activated.
5.
In the display (see Chapter 9 for details), find the "SETTINGS" menu. Select "Change NumCAN". Press
OK. When prompted by the display, enter the installer code (3725) and press OK. Input the inverter node. If it was
a replaced inverter, proceed to the next step. If the set-up was for the inverters of a unit dependant on another unit,
repeat the process for each inverter.
6.
Reset the alarms. To do so, close the Q4 thermomagnetic circuit breaker and connect the optical fibre
cables. Alarm 1000 will remain.
7.
Once all units are properly configured and connected by fibre optic communication cable, connect the unit
after making the checks stipulated in Chapter 6, Commissioning.

5.5.2. Configuring the Modbus Node of an electronic block

Once the unit is properly wired, with CAN assigned and connected at least to the PV array:
1.
Check that the communication elements are in proper working order.
2.
In the "SETTINGS" menu. Select "Change inverter number" and introduce the right one.
3.
Check that the communication also works with the new node number.