Ingeteam Ingecon Sun 250 TL Installation Manual page 65

Table of Contents

Advertisement

Installation manual
Ensure adequate ventilation of the unit
Checking the status of exhaust fans, cleaning and replacing them if necessary.
Clean vents grids
Check the state of the filters in the front and side ventilation grids.
To do this you must first remove the grille of the air intake, behind which is the filter.
Unscrew the four nuts from the grid, accessible from the inside of the door.
Remove the grid.
Remove the filter from inside the grid.
Accumulated dust and dirt in the filter may adversely affect the cooling ability of the fan and result in anomolous
heating of the equipment. To solve this problem, clean and replace the filter and grid:
With a moderately dirty, dry filter, lightly tap until the dirt has been removed.
If the dirt does not disappear, wash in water at 40 °C.
If the filter is soiled with grease or oil, replace it with a new one.
If the problem persists, contact Ingeteam Energy, S.A.
When on, the inverter generates a buzzing sound.
Check the environment to avoid amplifying or transmitting the buzz.
The unit should be located in a place readily accessible for installation and maintenance work, enabling keyboard
handling, display reading and access to the unit's various internal components.
AAV2000IKI01
Ingeteam Energy, S.A.
65

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents