Ingeteam Energy, S.A.
Ingecon
Sun 500 TL NAC, 625HE TL NAC, 730HE TL NAC, 800HE TL NAC and 840HE TL NAC
®
Optional fixing
The Ingecon
Sun Power Max units have an optional fixing system.
®
The system comprises some plates that bolt the four corners of the base to the concrete pad where the inverter sits.
The following stipulations must be followed when choosing the place where the unit is to be bolted in:
Minimum distance from the centre of the bore to the edge of the concrete pad: 72 mm
Diameter of the hole drilled in the concrete pad: 8 mm
Minimum depth of the hole drilled in the concrete pad: 65 mm
Minimum thickness of the concrete pad: 100 mm
Minimum depth of anchoring bolt: 45 mm
18