CHAPTER 4

SOFTWARE CONFIGURATION

There are two main methods that can be used to complete the STS320 installation.
The first regards stations that do not need any application specific parameter configura-
tion. The factory default configuration is sufficient and the only necessary steps are to
align the Master IP Address to the Host LAN through a web browser using the Web Dis-
covery feature, then backup the configuration through the CBX500 menu.
The second method requires installation of the DL.CODE configuration program.
Through DL.CODE, IP Addresses are aligned, application specific parameters are config-
ured, and backup procedures are performed both to the external storage device
(BM100), as well as to a file.

STS320 DEFAULT CONFIGURATION

Default IP Address
Code symbologies
Layout type
Operating mode
Acquisition trigger
Data collection type
Output

CONFIGURATION USING WEB DISCOVERY

Devices can be discovered via web interface. To do this, from either the Host PC or con-
figuration PC connected to the network, open your browser and go to http://data-
logic.local/.
16 STS320
192.168.3.100
CODE128, CODE39, INT2OF5 (min. 8 digits)
Synchronized
Phase mode
Phase ON: Input 1 - Leading Edge
Phase OFF: Input 2 - Trailing Edge
Periodic (25 ms)
Code combination (1 expected code)
Good Read: Output 2, Green Spot, 360° Green Feedback
No Read: Output 1, Red Spot, 360° Red Feedback
Configuration Mode: 360° Blue Feedback
Event Type: Good Read, Output Channel: TCP Server (port 51236),
Output Message 1
Message content: <STX><CodeContent><CR><LF>
Event Type: No Read, Output Channel, TCP Server (port 51236),
Output Message 2
Message content: <STX><CAN><CR><LF>