Reset Reader To Factory Default (Optional) - Datalogic MATRIX 450 Reference Manual

Hide thumbs Also See for MATRIX 450:
Table of Contents

Advertisement

RAPID CONFIGURATION
Learn
8.
Enter the Learn function by pressing and holding the X-PRESS™ push button until the
Learn LED is on.
9.
Release the button to enter the Learn function. The Learn LED will blink until the
procedure is completed.
The Learn procedure ends when the Image Processing and Decoding parameters are
successfully saved in the reader memory, the Learn LED will remain on continuously, the
Green Spot is activated and Matrix 450™ emits 3 high pitched beeps
If the autolearning cannot be reached after a timeout of about 3 (three) minutes Matrix
450™ will exit without saving the parameters to memory, the Learn LED will not remain on
continuously but it will just stop blinking. In this case Matrix 450™ emits a long low pitched
beep.
10. Exit the Learn function by pressing the X-PRESS™ push button once.
If you have used this procedure to configure Matrix 450™ go to step 9.
NOTE

RESET READER TO FACTORY DEFAULT (OPTIONAL)

If it ever becomes necessary to reset the reader to the factory default values, you can
perform this procedure by holding the X-PRESS™ push button pressed while powering up
the reader. You must keep the X-PRESS™ push button pressed until the power up
sequence is completed (several seconds) and all LEDs blink simultaneously 3 times.
All LEDs remain on for about one second, then off for one second, the Configuration and
Environmental parameters are reset, and the status LED remains on. If connected through a
CBX500 with display module, the message "Default Set" is shown on the display.
1
The Learn procedure will not recognize Pharmacode symbologies.
red
yellow yellow green green
STATUS
COM
TRIGGER
TEST
FOCUS
Figure 12 – X-PRESS™ Interface: Learn Function
GOOD
READY
SETUP
LEARN
1
.
1
11