Renesas QB-MINI2 User Manual page 163

On-chip debug emulator with programming function
Hide thumbs Also See for QB-MINI2:
Table of Contents

Advertisement

CHAPTER
(4) Connecting the USB cable
Connect MINICUBE2 to the host machine as shown in Figure 6-18, before the power to the target system is
turned on.
When the power select switch is set to "T", the mode LED flashes white after connection.
When the power select switch is set to "3" or "5", the mode LED glows white after connection. The power is
always supplied after MINICUBE2 is connected to the host machine with the USB cable.
Caution
Do not change the switch setting while the USB cable is connected.
Figure 6-18.
MINICUBE2
MINICUBE2
(5) Applying power to target system
Turn on power to the target system. This step is not necessary if the power select switch is set to "3" or "5".
The mode LED glows white after power application.
(6) QB-Programmer startup
Start the QB-Programmer from the Start menu of Windows.
QB-Programmer startup.
A series of basic operations after this step is described in the following section. For detailed usage of the
QB-Programmer, refer to the QB-Programmer Programming GUI Operation User's Manual.
6
HOW TO USE MINICUBE2 WITH 78K0R MICROCONTROLLER
Connecting MINICUBE2 to Host Machine
USB cable
USB cable
User's Manual
U18371EJ5V0UM
Host machine
Host machine
The mode LED glows green after
161