Page 1
All information contained in these materials, including products and product specifications, represents information on the product at the time of publication and is subject to change by Renesas Electronics Corp. without notice. Please review the latest information published by Renesas Electronics Corp. through various means, including the Renesas Electronics Corp.
Page 2
Renesas Electronics. Renesas Electronics shall not be in any way liable for any damages or losses incurred by you or third parties arising from the use of any Renesas Electronics product for an application categorized as “Specific”...
Page 3
General Precautions for Handling This Product 1. Circumstances not covered by product guarantee • If the product was disassembled, altered, or repaired by the customer • If it was dropped, broken, or given another strong shock • Use at overvoltage, use outside guaranteed temperature range, storing outside guaranteed temperature range •...
Page 4
PDF file and specifying it in the “Find what:” field. To know the manipulations, command functions, and other software-related settings of the QB-78F1030 → See the user’s manual of the debugger (supplied with the QB-78F1030) to be used. Conventions...
Page 5
Caution The related documents listed above are subject to change without notice. Be sure to use the latest version of each document for designing, etc. IECUBE is a registered trademark of Renesas Electronics Corporation in Japan and Germany. Windows is either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries.
2.5.4 Precautions for handling TC, YQ, SA, and CA .................19 2.5.5 Precautions for mounting IC using TC and MA ................20 Connecting QB-78F1030 to Target System ................21 Notes on Power Supply and GND Pin Connection ............... 24 Connecting USB Interface Cable and AC Adapter..............24 Switching Power On and Off ....................
CHAPTER 1 GENERAL CHAPTER 1 GENERAL The QB-78F1030 is an in-circuit emulator for emulating the 78K0R/Kx3-L. Hardware and software can be debugged efficiently in the development of systems in which the 78K0R/Kx3-L is used. This manual descries basic setup procedures, hardware specifications, system specifications, and how to set switches.
QB-78F1030 CHAPTER 1 GENERAL System Specifications This section shows the QB-78F1030 system specifications. Table 1-2. QB-78F1030 System Specifications Parameter Specification Emulation memory capacity Internal ROM 512 KB (MAX.) Internal RAM 61.75 KB (MAX.) Program execution functions Real-time execution function Go, Start from Here, Come Here, Restart, Return Out, Ignore break points and Go Non-real-time execution function Step In, Next Over, Slowmotion, Go &...
QB-78F1030 CHAPTER 1 GENERAL System Configuration This section shows the system configuration when using the QB-78F1030 connected to a PC (PC/AT compatible). Connection is possible even without optional products. Figure 1-1. System Configuration <1> <3> <5> <4> <2> <6> <7>...
Page 11
QB-78F1030 CHAPTER 1 GENERAL Remarks 1. Obtain device files from the Renesas Electronics website. http://www2.renesas.com/micro/en/ods/ 2. Refer to 1.5 Package Contents for the purchase forms of the above products. 3. As for handling of connectors, refer to 2.5 Mounting and Connecting Connectors.
QB-78F1030 CHAPTER 1 GENERAL System Configuration for Each Target Device The following table lists the system configuration for each target device of the QB-78F1030. Table 1-3. Adapters and Connectors for Each Target Device Target Device Package Exchange Adaptor Space Adaptor...
QB-78F1030 CHAPTER 1 GENERAL Package Contents The included products are described for each order product name. Products supplied with QB-78F1030-ZZZ QB-78F1030 USB interface cable (2 meters) Online user registration card (warranty card and software contract in one) ID78K0R-QB Disk (CD-ROM)
QB-COMMON-PW-TW Notes 1. Products are shipped only on order from each region. 2. Contact a distributor or an Renesas Electronics sales representative for information on regions other than the above. 3. Only the AC adapter usable in each region can be ordered.
CHAPTER 2 SETUP PROCEDURE CHAPTER 2 SETUP PROCEDURE This chapter explains the QB-78F1030 setup procedure. Setup can be completed by performing installation setup in the order in which it appears in this chapter. Perform setup along the lines of the following procedure.
QB-78F1030 CHAPTER 2 SETUP PROCEDURE 2.1 Names and Functions of Hardware Figure 2-1. Names of Parts of QB-78F1030 Top View Bottom View Power switch OSC1 POWER TARGET TCN3 TCN2 TCN1 Side View Power supply connector USB connector R20UT0289JJ0100 Rev. 1.00...
Page 17
This is a connector for the shipment inspection. It is not something that the user will need. (4) POWER (Red LED) This is an LED that shows whether the power supply of the QB-78F1030 is switched on. LED State QB-78F1030 State...
CHAPTER 2 SETUP PROCEDURE Removal of Acrylic Board To modify the clock setting, the acrylic board on the bottom of the QB-78F1030 must be removed. The acrylic board can be removed by lifting it up. Figure 2-2. Acrylic Board Removal Method R20UT0289JJ0100 Rev.
QB-78F1030 CHAPTER 2 SETUP PROCEDURE Clock Settings The following four types of clock settings are available. Each clock setting is listed below. Clock Used Clock Supply Debugger Setting (in Configuration Dialog) Note 1 (1) High-speed system clock (a) When the clock generated within the emulator is used...
Page 20
QB-78F1030 CHAPTER 2 SETUP PROCEDURE (1) High-speed system clock The clock settings are listed below. Table 2-1. Settings for High-Speed System Clock Type of Clock to Be Used OSC1 Debugger Setting (a) When the clock generated within the emulator is used –...
Page 21
QB-78F1030 CHAPTER 2 SETUP PROCEDURE Figure 2-3. Oscillator Shape Top View Figure 2-4. Mapping of Oscillator to Socket Oscillator Socket Oscillator OSC1 Pin Number CLOCK OUT CLOCK OUT Remark Insert the oscillator into the socket, take care for the pin 1 position.
QB-78F1030 CHAPTER 2 SETUP PROCEDURE (3) Subsystem clock The clock settings are listed below. Table 2-2. Settings for Subsystem Clock Type of Clock to Be Used Debugger Setting (a) When the clock generated within the emulator is used System Note...
QB-78F1030 CHAPTER 2 SETUP PROCEDURE Mounting and Connecting Connectors This section describes the methods of connecting the QB-78F1030 and target system. Make connections with both the QB-78F1030 and target system powered OFF. The following abbreviations are used in this section:...
QB-78F1030 CHAPTER 2 SETUP PROCEDURE 2.5.2 Mounting YQ to TC (1) After confirming that there are no broken or bent YQ contact pins, fit the YQ in the TC and fasten it using the supplied YQGUIDE (for the fastening method, see the next step, (2)). If repeatedly inserting and removing, be sure to inspect the YQ pins before fitting.
QB-78F1030 CHAPTER 2 SETUP PROCEDURE 2.5.3 Plugging EA into YQ Match the pin 1 position of the YQ or SA (corner cuts match in both) to the pin 1 position of the EA and plug in. - When plugging or unplugging, press on the TC, YQ, and SA with a finger so that there is no force on the TC.
QB-78F1030 CHAPTER 2 SETUP PROCEDURE 2.5.5 Precautions for mounting IC using TC and MA (1) Confirm that there is no weld flash in the resin (sealant part) of the IC. If there is weld flash, remove it using a knife or the like.
There are two GND wires in the emulation probe. Connect them to the QB-78F1030 and target system. <1> Fasten the GND wire on the QB-78F1030 side of the emulation probe to the nut on the bottom of the QB-78F1030 using a #0 or #1 Phillips precision screwdriver (connection of B to A in Figure 2-6).
Page 28
QB-78F1030 CHAPTER 2 SETUP PROCEDURE Figure 2-6. GND Wire QB-78F1030 Target system <3> Connect the exchange adapter and emulation probe to the target connector. <4> Connect the GND wire on the target system side of the emulation probe to the target system GND.
Page 29
(c) Ensuring isolation When connecting the target system to the QB-78F1030 using an emulation probe, perform height regulation using the front spacer or rear spacer of the QB-78F1030 and ensure islation from the target system. Figure 2-8. Connection Using Emulation Probe...
<2> Be sure to connect the GND wire of the emulation probe to the QB-78F1030 and the target system. If it cannot be connected, the impedance of the cable is unstable and could bring about lowering of signal transmission characteristics or distortion of the output waveform for an input waveform.
QB-78F1030 CHAPTER 3 SETTINGS AT PRODUCT SHIPMENT CHAPTER 3 SETTINGS AT PRODUCT SHIPMENT Table 3-1. Settings at Shipment Item Setting Remarks Note Not mounted Oscillator can be mounted OSC1 Power switch Set to OFF at shipment. Note The oscillation circuit using an oscillation cannot be used.
When debugging is performed by connecting the QB-78F1030 to the target system, the QB-78F1030 emulates the target device as if it operates in the target system. However, the target device and the QB-78F1030 operate differently in the following ways. Consequently, the target device should be used for final evaluation before launching mass production, and the customer is to be responsible for judging the appropriateness of applying the QB-78F1030.
QB-78F1030 CHAPTER 4 CAUTIONS 4.1.7 Absolute maximum rating of p62 pin The absolute maximum rating of the P62 pin differs between the target device and emulator. IECUBE may be damaged if a voltage greater than 5.5 V is applied. Table 4-3. Absolute maximum rating of P62 pin...
QB-78F1030 CHAPTER 4 CAUTIONS 4.1.11 A/D converter scan mode If a break occurs while using the A/D converter in scan mode, the A/D converter is not stopped even during the break. Consequently, it cannot be ascertained which value stored in the conversion result register is the conversion result of the ANI pin.
Page 35
REVISION HISTORY Revisions up to the previous edition are shown below. The “Applied to” column indicates the chapter in each edition to which the revision was applied. Edition Description Applied to Rev.1.00 First Edition issued.
Page 37
SALES OFFICES Refer to "http://www.renesas.com/" for the latest and detailed information. Renesas Electronics America Inc. 2880 Scott Boulevard Santa Clara, CA 95050-2554, U.S.A. Tel: +1-408-588-6000, Fax: +1-408-588-6130 Renesas Electronics Canada Limited 1101 Nicholson Road, Newmarket, Ontario L3Y 9C3, Canada...