turns off and stops scanning after a good read. If you scan Do Not End
Character Activation After Good Read, the laser remains on after a
good read. Default = End Character Activation After Good Read.
Do Not End Character Activation
After Good Read

Character Activation Laser Timeout

You can set a timeout for the length of time the laser remains on and
attempting to decode bar codes when using Character Activation Mode. Set
the length (in milliseconds) for a timeout by scanning the following bar code,
then setting the timeout (from 1-65535 milliseconds) by scanning dig-its from
the
Programming

Character Deactivation Mode

If you have sent a character from the host to trigger the engine to begin scan-
ning, you can also send a deactivation character to stop scanning. Scan the
fol-lowing On bar code to use character deactivation, then use Deactivation
Character (following) to select the character you will send from the host to
termi-nate scanning. Default = Off.
* Off

Deactivation Character

This sets the character used to terminate scanning when using Character
Deactivation Mode. On the
value that represents the character you want to use to terminate scanning.
Chart, then scanning Save. Default = 5000 ms.
Character Activation Laser
Timeout
ASCII Conversion
* End Character
Activation After
Good Read
On
Chart, page A-3, find the hex