When Check Digit is set to Validate and Transmit, the engine only
reads NEC 2 of 5 bar codes printed with a check digit, and will transmit
this digit at the end of the scanned data. Default = No Check Digit.
* No Check Digit
Validate and Transmit
NEC 2 of 5 Redundancy
If you are encountering errors when reading NEC 2 of 5 bar codes, you
may want to adjust the redundancy count. Redundancy adjusts the num-
ber of times a bar code is decoded before transmission, which may
reduce the number of errors. Note that the higher the redundancy count,
the lon-ger it will take to decode the bar code. To adjust the redundancy,
scan the NEC 2 of 5 Redundancy bar code below, then scan a
redundancy count between 0 and 10 on the
the back cover of this manual. Then scan the
NEC 2 of 5 Message Length
Scan the bar codes below to change the message length. Refer to
Message Length Description
mum and Maximum lengths = 1-80. Minimum Default = 3, Maximum
Default = 80.
Minimum Message Length
NEC 2 of 5 Redundancy
(page 6-2) for additional information. Mini-
Validate, but Don't Transmit
Programming Chart
Save
bar code. Default = 0.
Maximum Message Length