End Character Activation After Good Read

After a bar code is successfully detected and read from the scanner, the illumination can be programmed either to remain
on and scanning, or to turn off. When End Character Activation After Good Read is enabled, the illumination turns off
and stops scanning after a good read. If you scan Do Not End Character Activation After Good Read, the illumination
remains on after a good read. Default = Do Not End Character Activation After Good Read.
* Do Not End Character
Activation After Good Read

Character Activation Timeout

You can set a timeout for the length of time the illumination remains on and attempting to decode bar codes when using
Character Activation Mode. Set the length (in milliseconds) for a timeout by scanning the following bar code, then setting
the timeout (from 1-300,000 milliseconds) by scanning digits from the
manual, then scanning Save. Default = 30,000 ms.

Character Deactivation Mode

If you have sent a character from the host to trigger the scanner to begin scanning, you can also send a deactivation character
to stop scanning. Scan the following On bar code to use character deactivation, then use Deactivation Character (following) to
select the character you will send from the host to terminate scanning. Default = Off.
* Off
3 - 6
Programming Chart
Character Activation Timeout
End Character Activation After
Good Read