Example:
What is the range of possible values for Codabar Coding Enable?
Enter:
cbrena*.
Response: CBRENA0-1[ACK]
This response indicates that Codabar Coding Enable (CBRENA) has a range
of values from 0 to 1 (off and on).
Example:
What is the default value for Codabar Coding Enable?
Enter:
cbrena^.
Response: CBRENA1[ACK]
This response indicates that the default setting for Codabar Coding
Enable (CBRENA) is 1, or on.
Example:
What is the device's current setting for Codabar Coding Enable?
Enter:
cbrena?.
Response: CBRENA1[ACK]
This response indicates that the device's Codabar Coding Enable (CBRENA)
is set to 1, or on.
Example:
What are the device's settings for all Codabar selections?
Enter:
cbr?.
Response: CBRENA1[ACK],
SSX0[ACK],
CK20[ACK],
CCT1[ACK],
MIN2[ACK],
MAX60[ACK],
DFT[ACK].
This response indicates that the device's Codabar Coding Enable (CBRENA)
is set to 1, or on;
the Start/Stop Character (SSX) is set to 0, or Don't
Transmit; the Check Character (CK2) is set to 0, or Not
Required; concatenation (CCT) is set to 1, or Enabled;
the Minimum Message Length (MIN) is set to 2 characters;
the Maximum Message Length (MAX) is set to 60
characters; and the Default setting (DFT) has no value.

Serial Trigger Commands

You can activate and deactivate the engine with serial trigger commands. The
button is activated and deactivated by sending the following commands:
Activate:
SYN T CR
Deactivate: SYN U CR
9 - 3