3.1.2 Assembly of Discrete-Wire Connector

The wire end can be directly press-fitted without removing the wire's insulation, saving labor.
Procedure:
1. Bend the contact back from the carrier, and set it in the pressure connection tool.
2. Insert the wire without removing its insulation until it stops, and lightly grip the tool.
3. After press-fitting the wire, insert it into the housing.
4. When all wires has been inserted, fit the semi-cover into place.