Warning codes are from 0xA000 to differentiate from the error codes.

15.4.1 Unit Warnings (From B000H)

These are the warning codes to be given when the warnings occurred in the positioning unit.
Error
Error name
code
B000H Tool operation
B010H Duplicate startup
J point
B030H
simultaneous
startup warning
Synchronous axis
B045H
difference check
warning
Moving amount
B046H
automatic check
warning
Recalculation
B304H
error warning
Description
The following request signals were
turned on by the host PLC during the
Tool operation.
- Positioning startup request flag
(each axis)
- Home return request flag (each
axis)
- JOG forward/reverse rotation
request flag (each axis)
The same axis was requested to
start even though the axis operation
has not completed.
"J point sepped change contact" and
J point positioning start contact" was
turned on simultaneously during the
JOG positioning (J point) operation.
The difference of the moving amount
of the target axis for the synchronous
operation exceeded the specified
threshold.
This warning occurs when setting the
synchronous operation method and
the synchronous difference check
function to "Warning".
The difference between the
command value and feedback value
exceeded the specified moving
amount automatic check value with
the moving amount automatic check
function.
This warning occurs when setting the
moving amount automatic check
operation to "Warning".
An error occurred during
recalculation processing.
A: Available N/A: Not available
Object Clear
Countermeasures
Various requests from the PLC
cannot be executed during the
Tool operation, except the
following requests.
- Deceleration stop request flag
Each
(each axis)
A
axis
- Emergency stop request flag
(each axis)
- System stop request flag (all
axes)
- Pulser operation enabled flag
(each axis)
The requests for the axes being
operated cannot be executed,
except the following requests.
- Deceleration stop request flag
Each
A
(each axis)
axis
- Emergency stop request flag
(each axis)
- System stop request flag (all
axes)
When the both contacts have
been turned on simultaneously, "J
Each
A
point positioning start contact"
axis
has a priority, and "J point speed
change contact" is ignored.
Each
Check the operation of the targe
A
axis
axis.
Each
Check the operation of the target
A
axis
axis.
Check the setting of parameters
Each
A
or interpolation group for each
axis
axis.