Wiring
 Pressure connection tool
Manufacturer
Product No.
Panasonic
AXY52000FP

3.3.2 Assembly of Connector for Wire-pressed Terminal Cable

The wire end can be directly crimped without removing the wire's insulation, saving labor.
(Procedure)
1. Bend the contact back from the carrier, and set it in the pressure connection tool.
2. Insert the wire without removing its insulation until it stops, and lightly grip the tool.
3. After press-fitting the wire, insert it into the housing.