17.5.2 Each Axis Information & Monitor Area
These are the areas for the information of each axis and monitoring operation states.
Axis information of axis 1
Offset
Bank
Name
address
External terminal
031H
input monitor of
axis 1
Moving amount
034H
automatic check
035H
value of axis 1
036H
Pulse input
value of axis 1
037H
Acitve table or
01H
038H
execution done
table of axis 1
Auxiliary output
039H
code of axis 1
Repeat count
03AH
setting value of
axis 1
Repeat count
03BH
current value of
axis 1
03CH
Current value of
axis 1
03DH
Unit system
03EH
conversion
current value of
03FH
axis 1
17-26
Descriptions
Stores the information of I/O connected to each axis.
Stores the maximum value of difference
between the command value and
feedback value of the unit.
Stores the pulse input values (pulser,
feedback pulse, couner) according to the
pulse input purposes.
The pulse input value is stored by
integrating the pulse input values until
changing the pulse input purpose or
clearing the pulse input.
Stores the number of active positioning
table or when the operation completed.
Stores the auxiliary output code.
Stores the setting value of repeat count
for positioning.
1 is stored not to repeat the operation.
When specifying the repeat count to be
unlimited, 255 is stored.
Stores the repeat count in operation.
1 is stored not to repeat the operation.
When the repeat count exceeds the
upper limit, it returns to 0.
Stores the current value.
Stores the current value after the unit
was converted.
Defaul
Setting
Unit
t value
range
-
-
-
-
-
pulse
1 to
1
-
600
0
-
0 to
0
times
255
0 to
0
times
65,535
0
-
pulse
0
-
-