Transfer multiple
With the FP2 positioning unit, this can be specified when the pulser operation function is used.
Outputting the number of pulses doubled by the number of pulser input signals, the transfer multiple is
said to be "2", and when the number of pulses is five times that of the pulser input signals, the transfer
multiple is said to be "5".
Example: Transfer multiple function of the FP positioning unit pulser input
Feedback pulse input
This counts the feedback pulse from the encoder. 2-phase input, direction distinction input and individual
input can be handled.
2-phase input method
This counts the signal of 2 pulses in the different phase (A phase, B phase). when A phase preceeds B
,
phase
the motor is rotated clockwise(count increment) and when B phase preceeds A phase, the
motor is rotated counter-clockwise (count decrement).
Direction distinction input method
This is a method to count using ON/OFF signal specifying the pulse signal and count direction.
Individual input method
This is a method to count using the count increment pulse signal and the count decrement pulse signal.