Panasonic FP2-PP2T Technical Manual page 227

Fp2 positioning unit (interpolation), programmable controller
Table of Contents

Advertisement

Offset
Name
address
048H
Pulser operation
maximum speed
049H
04AH
Coordinate
origin value
04BH
04CH
-
04DH
-
04EH
-
04FH
-
Starting address of each positioning parameter
Axis 1
Axis 2
Bank No.
02H
0CH
Descriptions
The maximum speed when selecting the speed limit for the pulser operation
method.
When the speed calculated by multiplying (pulser operation numerator / pulser
operation denominator) by the pulser input is ver the specified maximum speed,
the operation is performed at the maximum speed.
Unit: Set unit X1000/s
Input range: 0 to 32767000 (pulse/s)
Default: 0
If this area has been set to 0, it is the minimum speed in the set unit.
*
Stores the coordinate origin value after the home return.
-
-
-
-
Axis 3
Axis 4
16H
20H
Address
Descriptions
050H
Starting address of parameters
Default
Setting
Unit
value
range
17-37