Home Return In Synchronous Operation - Panasonic FP2-PP2T Technical Manual

Fp2 positioning unit (interpolation), programmable controller
Table of Contents

Advertisement

8.3.2 Home Return in Synchronous Operation

The usable home return methods vary according to the synchronous mode to be used in the
synchronous operation.
Home return
method
DOG method 1
DOG method 2
DOG method 3
Limit method 1
Limit method 2
Home method
Data set method
Remarks
Home return when using synchronous mode A
In the synchronous mode A, the home return is performed for each axis individually.
[Procedure]
1. Disable the synchronous operation.
2. Execute the home return for the master axis and slave axis individually.
3. Enable the synchronous operation after confirming the completion of the home return for the master
and slave axes.
Home return when using synchronous mode B
In the synchronous mode B, the home return is performed simultaneously for the master and slave axes
by executing the home return for the master axis.
Connect the near home switch and limit switch as below to perform the home return using the "DOG
method 2" and "Limit method 2".
8-26
Synchronous mode A
A
A
A
A
A
A
A
Set the synchronous
operation to be "Disabled"
when performing the home
return.
A: Available
N/A: Not available
Synchronous mode B
N/A
A
N/A
N/A
A
N/A
A
The connections for each
switch are different when
using the home return.

Advertisement