Precautions on programming
The movement amount per an 1-pulse signal from the pulser can be changed by setting the ratio
-
numerator and ratio denominator for the input signal of the pulser.
The number of the startup contact and flag varies depending on the number of axes and the installation
-
position.
The specified slot number varies depending on the installation position of the unit.
-
Operation at limit input
Condition
When Pulser operation
is executed
During Pulser operation
11-4
Direction
Limit status
Limit input(+):ON
Forward
Limit input (-):ON
Limit input(+):ON
Reverse
Limit input (-):ON
Forward
Limit input(+):ON
Reverse
Limit input (-):ON
Operation
Not executable. Error occurs.
Executable
Executable
Not executable. Error occurs.
Deceleration stop. Error occurs.
Deceleration stop. Error occurs.