Panasonic FP2-PP2T Technical Manual page 154

Fp2 positioning unit (interpolation), programmable controller
Table of Contents

Advertisement

Precautions on programming
The movement amount per an 1-pulse signal from the pulser can be changed by setting the ratio
-
numerator and ratio denominator for the input signal of the pulser.
The number of the startup contact and flag varies depending on the number of axes and the installation
-
position.
The specified slot number varies depending on the installation position of the unit.
-
Operation at limit input
Condition
When Pulser operation
is executed
During Pulser operation
11-4
Direction
Limit status
Limit input(+):ON
Forward
Limit input (-):ON
Limit input(+):ON
Reverse
Limit input (-):ON
Forward
Limit input(+):ON
Reverse
Limit input (-):ON
Operation
Not executable. Error occurs.
Executable
Executable
Not executable. Error occurs.
Deceleration stop. Error occurs.
Deceleration stop. Error occurs.

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents