[Drive recorder history power on time (Obj. 2A70h: 03h)]

Data Type
Access
U32
RO
Description
Returns the cumulative time that the drive recorder has been turned on. When there is no history, "00000000h" is returned.

[Drive recorder history time (second) (Obj. 2A70h: 04h)]

Data Type
Access
U32
RO
Description
The time at when recorded data in the drive recorder is returned as a 32-bit integer (time passed from January 1, 1970,
0:00:00.000000000).
If time data cannot be obtained from the network, alarm occurrence time shows the cumulative power-on time from January 1,
1970, 0:00:00.000000000.
Use this object together with [Drive recorder history time (nanosecond) (Obj. 2A70h: 05h)] according to the system.

[Drive recorder history time (nanosecond) (Obj. 2A70h: 05h)]

Data Type
Access
U32
RO
Description
Returns the digits after the ones indicating a second in the recording time of the drive recorder as a 32-bit integer. A value is
returned in units of nanoseconds, but only the values in milliseconds increase.
For example, if an alarm occurs on January 1, 2000, 12:00:00.001, "000F4240h (1000000)" will be returned.

[Drive recorder history (time zone) (Obj. 2A70h: 06h)]

Data Type
Access
I32
RO
Description
Returns the time zone when data was recorded using the drive recorder.
If no setting exists, "80000000h" will be returned.

[Drive recorder history (summer time) (Obj. 2A70h: 07h)]

Data Type
Access
I32
RO
Description
Returns the daylight saving time at when recorded data in the drive recorder.
If no setting exists, "80000000h" will be returned.
Mapping
Default
Impossible
00000000h
Mapping
Default
Impossible
00000000h
Mapping
Default
Impossible
00000000h
Mapping
Default
Impossible
00000000h
Mapping
Default
Impossible
00000000h
Range
Units
00000000h to
FFFFFFFFh
Range
Units
00000000h to
FFFFFFFFh
Range
Units
00000000h to
FFFFFFFFh
Range
Units
80000000h to
minute
7FFFFFFFh
Range
Units
80000000h to
minute
7FFFFFFFh
6.8 [Drive recorder history newest (Obj. 2A70h)]
Save
Parameter
Impossible
Save
Parameter
Impossible
Save
Parameter
Impossible
Save
Parameter
Possible
Save
Parameter
Possible