Friction Based Fault Prediction Upper Threshold (Obj. 2C2Ah)]; [Friction Based Fault Prediction Upper Threshold (Obj. 2C2Ah: 00H)]; Friction Based Fault Prediction Lower Threshold (Obj. 2C2Bh)]; [Friction Based Fault Prediction Lower Threshold (Obj. 2C2Bh: 00H)] - Mitsubishi Electric MELSERVO-J5 Series User Manual

Ac servo system
Hide thumbs Also See for MELSERVO-J5 Series:
Table of Contents

Advertisement

8.17
[Friction based fault prediction upper threshold
(Obj. 2C2Ah)]
[Friction based fault prediction upper threshold (Obj. 2C2Ah:
00h)]
Data Type
Access
I32
RO
Description
The upper limit threshold for friction failure prediction is returned.
8.18
[Friction based fault prediction lower threshold
(Obj. 2C2Bh)]
[Friction based fault prediction lower threshold (Obj. 2C2Bh:
00h)]
Data Type
Access
I32
RO
Description
The lower limit threshold for friction failure prediction is returned.
8.19
[Friction based fault prediction prepare status
(Obj. 2C2Ch)]

[Friction based fault prediction prepare status (Obj. 2C2Ch: 00h)]

Data Type
Access
I16
RO
Description
The preparation progress for friction failure prediction is returned.
8.20
[Vibration based fault prediction threshold (Obj.
2C2Dh)]

[Vibration based fault prediction threshold (Obj. 2C2Dh: 00h)]

Data Type
Access
I32
RO
Description
The threshold for vibration failure prediction is returned.
Mapping
Default
Impossible
Mapping
Default
Impossible
Mapping
Default
Impossible
Mapping
Default
Impossible

8.17 [Friction based fault prediction upper threshold (Obj. 2C2Ah)]

Range
Units
-2147483648 to
0.1 %
2147483647
Range
Units
-2147483648 to
0.1 %
2147483647
Range
Units
0 to 100
%
Range
Units
-2147483648 to
0.1 %
2147483647
8 Manufacturer Specific Control Object
Save
Parameter
Impossible
Save
Parameter
Impossible
Save
Parameter
Impossible
Save
Parameter
Impossible
8
67