Performing a PC calibration

To perform the PC calibration, complete the steps below.
ID
Part name
1
Test equipment
2
Test signal
3
Test pattern
4
Inspection item
1. On the IR remote keypad, press Menu and select Size & Position > Size Presets > Full
Size.
2. Enter Service mode.
See
Entering Service mode
3. Select ADC Calibration.
4. Press Enter.
After a few seconds, the ADC calibration status changes from Doing to Done.

Performing a video calibration

To perform the video calibration, complete the steps below.
ID
Part name
1
Test equipment
2
Test signal
3
Test pattern
4
Inspection items
1. On the IR remote keypad, press Menu and select Size & Position > Size Presets > Full
Size.
HS Series 2K Service Manual—DWU1612-HS,DWU2022-HS
020-001790-01 Rev. 1 (03-2020)
Copyright ©2020 Christie Digital Systems USA Inc. All rights reserved.
Description
Video generator (output level: 700 mv)
Timing: 800 x 600 @60Hz
16 Gray
Check if the ADC calibration status has changed from Doing to Done.
on page 19.
Description
Video generator (output level: 700 mv)
DWU1612-HS
; Analog 1920 x 1200 @60Hz
DWU2022-HS
; Analog 1920 x 1200 @60Hz
SMPTE BAR
Check if the ADC calibration status has changed from Doing to Done.
Service setups
24