Section 5
Control Side (Continued)
13
14
No.
Label Pictorial
13
14
SJ 82T & SJ 86T
Annual Inspection
Ensure that work platform has received annual inspection prior
to operation.
Emergency Lowering Procedure
Refer to Operating manual.
1. Pull out "
" emergency stop button.
2. Turn off/base/platform key switch to "
3. Select "
" emergency power position from start/function
enable/emergency power switch.
4. Activate desired boom function to lower platform.
Description
" base position.
Labels