Refueling Procedure - Skyjack SJ82T Operating Manual

Telescopic booms
Hide thumbs Also See for SJ82T:
Table of Contents

Advertisement

Section 3 - Operation

3.8 Refueling Procedure

This section provides the operator with the procedure
on how to refuel the engine.
Failure to heed the following safety
precautions could result in death or
serious injury:
• Use extreme caution while refueling
aerial platforms.
• Ensure that engine and all systems
are turned off before refueling.
• Refuel the aerial platform only in a
well ventilated area away from open
flame and other sources of ignition,
authorized by your employer and
supervisor.
• Never try to start an aerial platform if
you smell gasoline.
• Gasoline engine models:
Use only unleaded gasoline with an
octane rating 87 or higher.
• Diesel engine models:
Use ultra low sulfur fuel only.
Do not smoke in an area where aerial
platforms are stored or refueled.
When operating on a slope, ensure fuel
level is above half to avoid a possible
stall condition.
IMPORTANT
Before using your aerial platform ensure
there is enough fuel for expected use.
SJ 82T & SJ 86T
WARNING
WARNING
CAUTION
3.8-1
Refuelling (Gasoline or Diesel)
IMPORTANT
Use unleaded gasoline or ultra low sulfur
diesel as indicated on fuel tank.
1.
Ensure engine and all systems are turned off and
emergency stop buttons are depressed.
2.
Open control compartment and remove fuel cap.
3.
Carefully fill the fuel tank ensuring that no spillage
occurs.
4.
Secure fuel cap.
5.
Ensure there are no leaks in fuel system.
6.
Wipe up any spilled fuel.
7.
Dispose of rags in an approved container.
Refueling Procedure
Page 65