Skyjack SJ82T Operating Manual page 44

Telescopic booms
Hide thumbs Also See for SJ82T:
Table of Contents

Advertisement

Function Tests
High Capacity Indicator Light
Reset Button
Test Secondary Guarding Electrical (SGE)
(If Equipped)
1. Press the sensor bar for less than 1
second and then release.
Result: The audible/visual alarm should
activate while the bar is being pressed
and turn off after being released. The reset
button should illuminate as soon as the
sensor bar is pressed, and turn off when
the bar is released.
2. Press the sensor bar for more than 1
second and then release.
Result: The audible/visual alarm should
activate immediately and stay on after the
bar is released. The reset button should
illuminate. The engine fault and glow plug
indicator lights should illuminate.
3. Press the reset button.
Result: The audible/visual alarm and reset
button light should go off.
4. Start the engine.
5. Press the sensor bar for less than 1
second and then release.
Result: The audible/visual alarm should
activate while the bar is being pressed
and turn off after being released. The reset
button should illuminate as soon as the
sensor bar is pressed, and turn off when
the bar is released.
Page 44
It is the responsibility of the operator to read, completely understand and follow all instructions and warnings
Capacity Zone
Platform Capacity
Border Light
Selector Switch
contained in this operating manual and on the aerial platform.
Platform Leveling Override Switch
Low Capacity Indicator
Light
6. Press the sensor bar for more than 1
second and then release.
Result: The audible/visual alarm should
activate immediately and stay on after
the bar is released. The engine should
shut down after 1 second. The reset
button should illuminate. The engine fault
and glow plug indicator lights should
illuminate.
7. Press the reset button.
Result: The audible/visual alarm and reset
button light should go off.
8. Start the engine.
9. Activate any drive function in high torque
"
".
10. Press the sensor bar for less than 1
second and then release.
Result: The function will stop while the bar
is being pressed and motion will resume
when the bar is released. The audible/
visual alarm should activate while the
bar is being pressed and turn off after
being released. The reset button should
illuminate as soon as the sensor bar is
pressed, and turn off when the bar is
released.