Skyjack SJ82T Operating Manual page 35

Telescopic booms
Hide thumbs Also See for SJ82T:
Table of Contents

Advertisement

Section 2 - Familiarization
Platform Capacity
Selector Switch
High Capacity Zone
Indicator Light
Capacity Zone Border
Test Platform Capacity Selector Switch
To perform this function test, ensure
there is sufficient space to fully raise and
extend boom.
Ensure boom is in stowed position to
begin this function test.
1. Ensure both "
are pulled out and "
Result: High capacity zone indicator light
should illuminate.
2. Turn off/base/platform key switch to
"
" base position.
3. Extend "
is reached.
Result: Boom should stop. High capacity
zone indicator light and capacity zone
border light should flash.
4. While boom is extended, ensure there are
no visible cracks in welds or structure and
there are no signs of deformation.
SJ 82T & SJ 86T
It is the responsibility of the operator to read, completely understand and follow all instructions and warnings
Light
NOTE
NOTE
"emergency stop buttons
" start engine.
" boom until restricted area
contained in this operating manual and on the aerial platform.
Low Capacity Zone
Indicator Light
5. Attempt to "
" lower boom.
Result: Lower function should not
operate.
6. Attempt to "
"extend boom.
Result: Extend function should not
operate.
7. Activate all other boom functions.
Result: All boom functions should
operate, except for "
"
" extend.
8. Select "low" platform capacity zone from
platform capacity selector switch.
Result: Capacity zone border light and
high capacity zone indicator light should
turn off. Low capacity zone indicator light
should illuminate.
9. Attempt to "
" extend and "
boom fully.
Result: Extend and lower functions should
operate.
10. Push in "
" emergency stop button.
Function Tests
" lower and
" lower