Skyjack SJ82T Operating Manual page 55

Telescopic booms
Hide thumbs Also See for SJ82T:
Table of Contents

Advertisement

Component Identification (Optional Equipment/Attachments)
3.5-7 Arctic Weather Package (If Equipped)
The heater plug is located in the engine compartment
near the engine.
Figure 3-7. Heater Plug
1.
Battery/Hydraulic Oil/Engine Oil Heater Plug -
This cord is plugged into the AC outlet at least 4
hours before starting engine when temperature
gets below -18°C (0°F).
3.5-8 Secondary Guarding Electrical (SGE) (If
Equipped)
The purpose of this device is to prevent sustained
involuntary operation of the lift, which may result from
accidental contact with the platform controls, and to
activate an alarm (audible/visual) to alert others of the
event.
This device will not prevent collision
or eliminate the potential for injuries
resulting from a collision.
2
Figure 3-8. Secondary Guarding Electrical (SGE)
Page 56
1
WARNING
3
1
1.
Sensor Bar - This bar is located in front of the
platform control console. When pressure is
applied to the sensor bar, it interrupts/halts all
functions.
2.
Reset Button - This button is located on the top
left corner of the platform control console. It lights
up when pressure is applied to the sensor bar for
more than 1 second. When depressed, it shuts off
the audible/visual alarm.
3.
Audible/Visual Alarm - This alarm is located on
the underside of the platform control console. It
activates when pressure is applied to the sensor
bar.
SGE Operation
1.
When pressure is applied to the sensor bar for
less than 1 second, the audible/visual alarm will
activate while the bar is being pressed, interrupting
all functions. The audible/visual alarm will turn off
after the sensor bar is released, and functions
will resume.
2.
When pressure is applied to the sensor bar for
more than 1 second, the audible/visual alarm
will activate and the engine will shut off, halting
all functions. The reset button will illuminate.
Emergency power functions remain active.
3.
After removing pressure from the bar, press the
reset button to shut off the audible/visual alarm
and resume all functions.