Function Tests
High Capacity Indicator Light
Test Platform Capacity Selector Switch
To perform this function test, ensure
there is sufficient space to fully raise and
extend boom.
Ensure boom is in stowed position to
begin this function test.
1. Ensure both "
are pulled out and "
Result: High capacity zone indicator light
should illuminate.
2. Depress and hold footswitch and
"
" extend boom until restricted area
is reached.
Result: Boom should stop. High capacity
zone indicator light and capacity zone
border light should flash.
3. Depress and hold footswitch and attempt
to "
" lower.
Result: Lower function should not
operate.
Page 42
It is the responsibility of the operator to read, completely understand and follow all instructions and warnings
Capacity Zone
Platform Capacity
Border Light
Selector Switch
NOTE
NOTE
"emergency stop buttons
"start engine.
contained in this operating manual and on the aerial platform.
Section 2 - Familiarization
Low Capacity Indicator
Light
4. Depress and hold footswitch and attempt
to "
" extend boom.
Result: Extend function should not
operate.
5. Depress and hold footswitch and activate
all other boom and steer functions.
Result: All boom and steer functions should
operate, except for "
"
" extend.
6. Pull and select "low" platform capacity
from platform capacity selector switch.
Result: Capacity zone border light and
high capacity zone indicator light should
turn off. Low capacity zone indicator light
should illuminate.
7. Depress and hold footswitch and attempt
to "
" extend and "
fully.
Result: Extend and lower functions should
operate.
8. Retract the boom completely.
9. Push in "
" emergency stop button.
" lower and
" lower boom