Function Tests
Platform Capacity
Selector Switch
High Capacity Zone
Indicator Light
Capacity Zone Border
11. Pull out "
"emergency stop button.
Result: Aerial platform should automatically
reset to "high" platform capacity zone.
High capacity zone indicator light and
capacity zone border light should flash.
12. Select "
position from start/function enable/
emergency power switch.
Result: High capacity zone indicator light
and capacity zone border light should
flash. All boom functions should operate,
except for "
extend.
13. Select "low" platform capacity zone from
platform capacity selector switch.
Result: Capacity zone border light and
high capacity zone indicator light should
turn off. Low capacity zone indicator light
should illuminate.
Page 36
It is the responsibility of the operator to read, completely understand and follow all instructions and warnings
Light
" emergency power
" lower and "
"
contained in this operating manual and on the aerial platform.
Section 2 - Familiarization
Low Capacity Zone
Indicator Light
14. Select "
" emergency power
position from start/function enable/
emergency power switch and activate
each boom function.
Result: Low capacity zone indicator
light should remain illuminated. All boom
functions should operate.
15. Start engine and retract boom fully.