Refueling Procedure; Refuelling (Gasoline Or Diesel); Propane - Skyjack SJ85 AJ Operating Manual

Hide thumbs Also See for SJ85 AJ:
Table of Contents

Advertisement

Refueling Procedure

6.4 Refueling Procedure
This section provides the operator with the procedure
on how to refuel the engine and remove/install a
propane cylinder.
CAUTION
When operating on a slope, ensure fuel level is
above half to avoid a possible stall condition.
IMPORTANT
Before using your MEWP ensure there is enough
fuel for expected use.
WARNING
Failure to heed the following safety precautions
could result in death or serious injury:
Use extreme caution while refueling MEWPs.
Ensure that engine and all systems are turned
off before refueling.
Refuel the MEWP only in a well ventilated
area away from open flame and other sources
of ignition, authorized by your employer and
supervisor.
Never try to start a MEWP if you smell
gasoline.
Gasoline engine models:
Use only unleaded gasoline with an octane
rating 87 or higher.
Diesel engine models:
Use ultra low sulfur fuel only.
Liquid propane gas fuel is a gas that is
heavier than air. It settles in low spots. Any
flame or spark could cause a fire.
When changing liquid propane gas cylinder,
check all connections for damage or missing
parts.
WARNING
Do not smoke in an area where MEWPs are stored
or refueled.
SJ85 AJ

6.4-1 Refuelling (gasoline or diesel)

IMPORTANT
Use unleaded gasoline or ultra low sulfur diesel as
indicated on fuel tank.
1. Ensure engine and all systems are turned off
and emergency stop buttons are depressed.
2. Open control compartment and remove fuel cap.
3. Carefully fill the fuel tank ensuring that no
spillage occurs.
4. Secure fuel cap.
5. Ensure there are no leaks in fuel system.
6. Wipe up any spilled fuel.
7. Dispose of rags in an approved container.

6.4-2 Propane

WARNING
Follow all local and federal regulations for propane
handling.
To remove a propane cylinder:
1. Ensure engine and all systems are turned off
and emergency stop button is depressed.
2. Turn propane cylinder's main valve clockwise to
shut off fuel supply to engine.
3. Start engine and allow it to stop naturally. Restart
engine to ensure fuel lines are empty.
4. Disconnect hose from empty propane
cylinder by detaching the coupling. Turn fitting
counterclockwise.
5. Loosen two propane cylinder straps by pulling
up on the metal clips. Disconnect straps from
hooks.
6. Remove the propane cylinder.