ProSoft Technology ControlLogix MVI56E-SMGC User Manual page 12

Enhanced fmc722 tpu general communication module
Table of Contents

Advertisement

MVI56E-SMGC ♦ ControlLogix™ Platform
Enhanced FMC722 TPU General Communication Module
2
Click C
REATE
3
In the N
EW
Parameter
N
AME
D
ESCRIPTION
C
F
OMM
ORMAT
S
LOT
I
A
NPUT
SSEMBLY
I
S
NPUT
IZE
O
A
UTPUT
SSEMBLY
O
S
UTPUT
IZE
C
ONFIGURATION
C
ONFIGURATION
Important: You must select the C
not communicate over the backplane of the ControlLogix rack.
4
Click OK to continue.
ProSoft Technology, Inc.
. This action opens the N
M
dialog box, enter the following values.
ODULE
Value
Enter a module identification string. Example: SMGC
Enter a description for the module. Example: Enhanced SM
General Communication Module
Select D
Enter the slot number in the rack where the MVI56E-SMGC
module is located
1
I
NSTANCE
82
2
I
NSTANCE
28
4
A
I
SSEMBLY
NSTANCE
0
S
IZE
F
OMM
ORMAT
M
dialog box.
EW
ODULE
-INT
ATA
as D
- INT in the dialog box, otherwise the module will
ATA