ProSoft Technology MVI56E-61850S User Manual

ProSoft Technology MVI56E-61850S User Manual

Iec 61850 server communication module

Advertisement

Quick Links

MVI56E-61850S
ControlLogix Platform
IEC 61850 Server Communication
Module
September 3, 2014
USER MANUAL

Advertisement

loading
Need help?

Need help?

Do you have a question about the MVI56E-61850S and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ProSoft Technology MVI56E-61850S

  • Page 1 MVI56E-61850S ControlLogix Platform IEC 61850 Server Communication Module September 3, 2014 USER MANUAL...
  • Page 2 Neither ProSoft Technology nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein. Information in this document including illustrations, specifications and dimensions may contain technical inaccuracies or typographical errors.
  • Page 3 Important Safety Information North America Warnings Warning - Explosion Hazard - Substitution of components may impair suitability for Class I, Division 2. Warning - Explosion Hazard - When in Hazardous Locations, turn off power before replacing or rewiring modules. Warning - Explosion Hazard - Do not disconnect equipment unless power has been switched off or the area is known to be nonhazardous.
  • Page 5 Downloading the Project to the Module ..............42 3.11.1 Connecting Your PC to the Module's Ethernet Port ..........44 RSLogix 5000 Configuration MVI56E-61850S User-Defined Data Types ............49 MVI56E-61850S Controller Tags ................49 4.2.1 61850S Controller Tag Overview ................49 4.2.2...
  • Page 6: Diagnostics And Troubleshooting

    Contents MVI56E-61850S ♦ ControlLogix Platform User Manual IEC 61850 Server Communication Module Examples Data DB Example ....................53 SoE Example ......................58 Control Example ..................... 62 Diagnostics and Troubleshooting Ethernet LED Indicators ..................65 6.1.1 Scrolling LED Status Indicators ................66 6.1.2...
  • Page 7: In This Chapter

    : install and launch programs, execute menu commands, navigate dialog boxes, and enter data  Hardware installation and wiring: install the module, and safely connect IEC 61850 and ControlLogix devices to a power source and to the MVI56E-61850S module’s application port(s) ProSoft Technology, Inc. Page 7 of 81...
  • Page 8 Contents MVI56E-61850S ♦ ControlLogix Platform User Manual IEC 61850 Server Communication Module System Requirements The MVI56E-61850S module requires the following minimum hardware and software components:  ® ® Rockwell Automation ControlLogix processor (firmware version 10 or higher) with compatible limited voltage power supply and one free slot in the rack for the MVI56E- 61850S module.
  • Page 9 IEC 61850 Server Communication Module User Manual Package Contents The following components are included with your MVI56E-61850S module, and are all required for installation and configuration. Important: Before beginning the installation, please verify that all of the following items are present.
  • Page 10 Refer to the documentation for each device you plan to connect to verify that suitable safety procedures are in place before installing or servicing the device. After you have checked the placement of the jumpers, insert the MVI56E-61850S into the ControlLogix chassis. Use the same technique recommended by Rockwell Automation to remove and install ControlLogix modules.
  • Page 11 MVI56E-61850S ♦ ControlLogix Platform Contents IEC 61850 Server Communication Module User Manual Make a note of the slot location. You must identify the slot in which the module is installed in order for the sample program to work correctly. Slot numbers are identified on the green circuit board (backplane) of the ControlLogix rack.
  • Page 12 Contents MVI56E-61850S ♦ ControlLogix Platform User Manual IEC 61850 Server Communication Module Connecting Your PC to the ControlLogix Processor There are several ways to establish communication between your PC and the ControlLogix processor. The following steps show how to establish communication through the serial interface.
  • Page 13 MVI56E-61850S ♦ ControlLogix Platform Contents IEC 61850 Server Communication Module User Manual Downloading the Sample Program to the Processor Note: The key switch on the front of the ControlLogix processor must be in the REM or PROG position. If you are not already online with the processor, in RSLogix 5000 open the Communications menu, and then choose D .
  • Page 14 Contents MVI56E-61850S ♦ ControlLogix Platform User Manual IEC 61850 Server Communication Module 1.6.1 Configuring the RSLinx Driver for the PC COM Port When trying to connect serially, if RSLogix is unable to establish communication with the processor, follow these steps.
  • Page 15 MVI56E-61850S ♦ ControlLogix Platform Contents IEC 61850 Server Communication Module User Manual Click to select the driver, and then click C . This action opens the Configure ONFIGURE RS-232 DF1 Devices dialog box. Click the A button. RSLinx will attempt to configure your serial port to ONFIGURE work with the selected driver.
  • Page 16 Contents MVI56E-61850S ♦ ControlLogix Platform User Manual IEC 61850 Server Communication Module Page 16 of 81 ProSoft Technology, Inc. September 4, 2014...
  • Page 17 DMINISTRATOR instructions that appear on the screen. If you want to find additional software specific to your MVI56E-61850S, enter the model number into the website search box and press the Enter key. If you are installing PCB from the ProSoft Solutions DVD: Insert the ProSoft Solutions DVD into your computer's DVD drive and wait for the ProSoft Installation program to start.
  • Page 18 Contents MVI56E-61850S ♦ ControlLogix Platform User Manual IEC 61850 Server Communication Module Setting Up the Project To begin, start P (PCB). ONFIGURATION UILDER If you have used other Windows configuration tools before, you will find the screen layout familiar. PCB’s window consists of a tree view on the left, and an information pane and a configuration pane on the right side of the window.
  • Page 19 Module Type dialog box. In the Product Line Filter area of the dialog box, select MVI56E. In the Select Module Type dropdown list, select MVI56E-61850S, and then click OK to save your settings and return to the ProSoft Configuration Builder window.
  • Page 20 Contents MVI56E-61850S ♦ ControlLogix Platform User Manual IEC 61850 Server Communication Module Page 20 of 81 ProSoft Technology, Inc. September 4, 2014...
  • Page 21 61850S Data Control ................32  61850S Buffered Reports ..............34  61850S Unbuffered Reports ..............38  Downloading the Project to the Module ..........42 This chapter covers the MVI56E-61850S configuration within ProSoft Configuration Builder. ProSoft Technology, Inc. Page 21 of 81 September 4, 2014...
  • Page 22 Contents MVI56E-61850S ♦ ControlLogix Platform User Manual IEC 61850 Server Communication Module Backplane Configuration This section of the configuration describes the database setup and module-level parameters. Double-click the B icon to edit the parameters. ACKPLANE ONFIGURATION Name Range Description Write Register Count 0 to 4000 For Data DB objects.
  • Page 23 User Manual Ethernet1 In this step, you assign an IP address for the MVI56E-61850S module. This becomes the permanent IP address for the module after you download the configuration to the module. The module’s default IP address is 192.168.0.250. Determine the network settings for your module, with the help of your network administrator if necessary.
  • Page 24 Contents MVI56E-61850S ♦ ControlLogix Platform User Manual IEC 61850 Server Communication Module 61850S Identification This section allows you to assign unique IED identification parameters to the module. Double-click the 61850S I icon to edit the parameters. DENTIFICATION Name Description configVersion Version of the configuration.
  • Page 25 MVI56E-61850S ♦ ControlLogix Platform Contents IEC 61850 Server Communication Module User Manual 61850S Network This section allows you to set the parameters on incoming IEC 61850 client connections. Double-click the 61850S N icon to edit the parameters. ETWORK Name Range...
  • Page 26 Contents MVI56E-61850S ♦ ControlLogix Platform User Manual IEC 61850 Server Communication Module 61850S IP Filter This section allows you to create a whitelist or blacklist to allow/deny outside IP address connections. Double-click the 61850S IP F icon to edit the parameters.
  • Page 27 MVI56E-61850S ♦ ControlLogix Platform Contents IEC 61850 Server Communication Module User Manual If the IP Filter is enabled, you will need to configure the IP addresses to be filtered. Double-click the 61850S IP F icon. ILTER Click A then E to enter the IP address information.
  • Page 28 User Manual IEC 61850 Server Communication Module 61850S Data DB Configuration This section allows you to configure DB data objects (DO's) for the MVI56E-61850S. This data will be updated to the module from the processor. Double-click the 61850S D DB icon to open the configuration window.
  • Page 29 MVI56E-61850S ♦ ControlLogix Platform Contents IEC 61850 Server Communication Module User Manual Name Description Data Object This value identifies the 61850 data object (DO) instantiated from a 61850 CDC to which the data point is mapped. The data object number has to be set within a specific range according to its data type:...
  • Page 30 User Manual IEC 61850 Server Communication Module 61850S Data SoE This section allows you to configure SoE data objects (DO's) for the MVI56E-61850S. This data will be updated to the module from the processor. Double-click the 61850S D E icon to open the configuration window.
  • Page 31 MVI56E-61850S ♦ ControlLogix Platform Contents IEC 61850 Server Communication Module User Manual Name Description Data Object This value identifies the 61850 data object (DO) instantiated from a 61850 CDC to which the data point is mapped. The data object number has to be set within a specific...
  • Page 32 Contents MVI56E-61850S ♦ ControlLogix Platform User Manual IEC 61850 Server Communication Module 61850S Data Control This section allows you to you to configure Control data objects (DO's) for the MVI56E- 61850S. Control data originates from an IEC 61850 client. The module passes this data to the processor where it is acknowledged.
  • Page 33 MVI56E-61850S ♦ ControlLogix Platform Contents IEC 61850 Server Communication Module User Manual Name Description Data Object This value identifies the 61850 data object (DO) instantiated from a 61850 CDC to which the data point is mapped. The data object number has to be set within a specific range according to its data...
  • Page 34 Contents MVI56E-61850S ♦ ControlLogix Platform User Manual IEC 61850 Server Communication Module 61850S Buffered Reports A buffered report logs the changes in data if the IEC 61850 client/server connection has been lost. Once the connection has be re-established, the report can be sent upon condition.
  • Page 35 MVI56E-61850S ♦ ControlLogix Platform Contents IEC 61850 Server Communication Module User Manual Name Range Description Max Instances 0 to 8 Maximum number of instantiations of this RCB. The matching Report Control element is generated only if this value is non- zero.
  • Page 36 Contents MVI56E-61850S ♦ ControlLogix Platform User Manual IEC 61850 Server Communication Module 3.9.1 61850S BR0x Dataset This section allows you to set up datasets for data objects for buffered reports. Double-click the 61850S BR0 icon to open the configuration window.
  • Page 37 MVI56E-61850S ♦ ControlLogix Platform Contents IEC 61850 Server Communication Module User Manual Name Description Data Object This value identifies the 61850 data object (DO) number already configured at Instance "DATA DB" or SoE sections that will be included in this dataset.
  • Page 38 Contents MVI56E-61850S ♦ ControlLogix Platform User Manual IEC 61850 Server Communication Module 3.10 61850S Unbuffered Reports An unbuffered report logs a change in data if the IEC 61850 client/server connection has been lost. Once the connection has be re-established, only the last reported data change will be sent.
  • Page 39 MVI56E-61850S ♦ ControlLogix Platform Contents IEC 61850 Server Communication Module User Manual Name Range Description Max Instances 0 to 8 Maximum number of instantiations of this RCB. The matching Report Control element is generated only if this value is non- zero.
  • Page 40 Contents MVI56E-61850S ♦ ControlLogix Platform User Manual IEC 61850 Server Communication Module 3.10.1 61850S UR0x Dataset This section allows you to set up datasets for data objects for unbuffered reports. Double-click the 61850S BR0 icon to open the configuration window.
  • Page 41 MVI56E-61850S ♦ ControlLogix Platform Contents IEC 61850 Server Communication Module User Manual Name Description Data Object This value identifies the 61850 data object (DO) number already configured at Instance "DATA DB" or SoE sections that will be included in this dataset.
  • Page 42 In order for the module to use the settings you configured, you must download (copy) the updated Project file from your PC to the module. In the tree view in ProSoft Configuration Builder, right-click the MVI56E-61850S icon to open a shortcut menu.
  • Page 43 MVI56E-61850S ♦ ControlLogix Platform Contents IEC 61850 Server Communication Module User Manual If the Test Connection procedure fails, you will see an error message. To correct the error, follow these steps. Click OK to dismiss the error message. In the Download dialog box, click B ) to open ProSoft Discovery Service.
  • Page 44 OR reconfigure the router/ layer 3 switch to allow routing of the UDP broadcast messages. In the tree view in ProSoft Configuration Builder, select the MVI56E-61850S module. Page 44 of 81 ProSoft Technology, Inc.
  • Page 45 MVI56E-61850S ♦ ControlLogix Platform Contents IEC 61850 Server Communication Module User Manual Click the right mouse button to open a shortcut menu. On the shortcut menu, choose IAGNOSTICS In the Diagnostics window, click the S button. ONNECTION In the Connection Setup dialog box, click the B...
  • Page 46 Contents MVI56E-61850S ♦ ControlLogix Platform User Manual IEC 61850 Server Communication Module The module’s default IP address is 192.168.0.250. Choose an unused IP within your subnet, and then click OK. Important: The temporary IP address is only valid until the next time the module is initialized. For information on how to set the module’s permanent IP address, see Ethernet Configuration.
  • Page 47 You need to have RSLinx installed on your PC to use this feature. You also need an ENBT module set up in the rack. For information on setting up the ENBT module, see Using CIPconnect to Connect to the Module. In the tree view in ProSoft Configuration Builder, right-click the MVI56E-61850S module. From the shortcut menu, choose D...
  • Page 48 Contents MVI56E-61850S ♦ ControlLogix Platform User Manual IEC 61850 Server Communication Module Page 48 of 81 ProSoft Technology, Inc. September 4, 2014...
  • Page 49 MVI56E-61850S User-Defined Data Types ...........49  MVI56E-61850S Controller Tags ............49 Although the MVI56E-61850S configuration is done in PCB, it is maintained in the MVI56E61850S controller tags of RSLogix 5000. This chapter covers the tag structure and locations of the MVI56E-61850S parameters in RSLogix 5000.
  • Page 50 Examples (page 53). Data DB MVI56E61850S.DATA.DATA_DB. Description Database.WriteData[x] MVI56E-61850S database array written from processor to the module. Sequence of Event (SoE) MVI56E61850S.DATA.SOE. Description BOOL Array contains the tags to populate and trigger SoE Boolean data...
  • Page 51 MVI56E-61850S ♦ ControlLogix Platform Contents IEC 61850 Server Communication Module User Manual 4.2.3 MVI56E61850S.COMMAND This array includes the control of module time, control block acknowledgement, and reboot commands. Time operations for reading/writing time values between the processor and the module: MVI56E61850S.COMMAND.TIME.
  • Page 52 Contents MVI56E-61850S ♦ ControlLogix Platform User Manual IEC 61850 Server Communication Module 4.2.4 MVI56E61850S.STATUS Tag This array contains the overall module status. MVI56E61850S.STATUS. Description ScanCounter Scan counter increments at every module scan of the ladder logic BackplanePhase 0 = Running...
  • Page 53 MVI56E-61850S ♦ ControlLogix Platform Contents IEC 61850 Server Communication Module User Manual Examples In This Chapter  Data DB Example ..................53  SoE Example ..................58  Control Example ..................62 This chapter includes examples of setting up the module for Data DB, SoE, and Control data exchange.
  • Page 54 Contents MVI56E-61850S ♦ ControlLogix Platform User Manual IEC 61850 Server Communication Module In RSLogix 5000, edit the EDIT_MVI56E61850S_DATABASE_CONFIG User-Defined Data Type to 720: The MVI56E61850S.DATA.DATA_DB.Database.WriteData array now contains 720 elements. The sample ladder will adjust to accommodate the 3 data blocks needed.
  • Page 55 MVI56E-61850S ♦ ControlLogix Platform Contents IEC 61850 Server Communication Module User Manual For Boolean data, enter the following values. One bit of data will be allotted for this DO in the module's internal memory register 0, bit 0. This location corresponds to MVI56E61850S.DATA.DATA_DB.Database.WriteData[0].0 in RSLogix 5000.
  • Page 56 The MVI56E-61850S ladder logic sends these values over the backplane to the MVI56E- 61850S module memory on every scan. 10 Verify the values of the module memory by viewing the MVI56E-61850S database in the PCB. For more information, see Using the Diagnostics Menu in ProSoft Configuration...
  • Page 57 MVI56E-61850S ♦ ControlLogix Platform Contents IEC 61850 Server Communication Module User Manual 11 In the Diagnostics window, click on 61850 SERVER - DATA MAPPINGS > DB - Paths & Values. The DO and quality values are displayed here. ProSoft Technology, Inc.
  • Page 58 Contents MVI56E-61850S ♦ ControlLogix Platform User Manual IEC 61850 Server Communication Module SoE Example This example shows how to set up boolean, integer, and real Sequence of Event (SoE) data objects (DO's). In this section, you will configure the PCB file, edit events in RSLogix 5000, and verify the value has been updated in module memory.
  • Page 59 MVI56E-61850S ♦ ControlLogix Platform Contents IEC 61850 Server Communication Module User Manual With the processor in RUN mode in RSLogix 5000, locate the MVI56E61850S.DATA.SOE array. In order for the SoE data to be sent from the processor to the module, you must populate then trigger an event in this array.
  • Page 60 Contents MVI56E-61850S ♦ ControlLogix Platform User Manual IEC 61850 Server Communication Module Event[1]. Value Description PointID This value must match the corresponding INT Point ID parameter in PCB Reserved Not used at this time 0 = Good data, No bit set, 1 = Questionable, Old data bit set...
  • Page 61 Contents IEC 61850 Server Communication Module User Manual Verify the values in module memory by viewing the MVI56E-61850S database in the PCB. For more information, see Using the Diagnostics Menu in ProSoft Configuration Builder In the Diagnostics window, click on 61850 SERVER - DATA MAPPINGS > SoE - Paths &...
  • Page 62 5000, and verify the value has been populated in module memory using an automatic acknowledge feature. When a IEC 61850 client sends Control DO data to the MVI56E-61850S, the MVI56E- 61850S passes this data to the processor. This data can be analyzed by the user's ladder logic.
  • Page 63 MVI56E-61850S ♦ ControlLogix Platform Contents IEC 61850 Server Communication Module User Manual Save and download the PCB file to the module. For more information, see Downloading the Sample Program to the Processor (page 13) With the processor in RUN mode in RSLogix 5000, locate the MVI56E61850S.DATA.SOE array.
  • Page 64 17.17 Data value Verify the acknowledged data in module memory by viewing the MVI56E-61850S database in the PCB. For more information, see Using the Diagnostics Menu in ProSoft Configuration Builder In the Diagnostics window, click on 61850 SERVER - DATA MAPPINGS >...
  • Page 65: Table Of Contents

    MVI56E-61850S ♦ ControlLogix Platform Contents IEC 61850 Server Communication Module User Manual Diagnostics and Troubleshooting In This Chapter  Ethernet LED Indicators .................65  Clearing a Fault Condition ..............67  Troubleshooting ..................68  Using the Diagnostics Menu in ProSoft Configuration Builder ....69 ...
  • Page 66 Contents MVI56E-61850S ♦ ControlLogix Platform User Manual IEC 61850 Server Communication Module 6.1.1 Scrolling LED Status Indicators The scrolling LED display indicates the module’s operating status as follows: Initialization Messages Code Message Boot / DDOK Module is initializing Ladd Module is waiting for required module configuration data from...
  • Page 67: Clearing A Fault Condition

    Verify correct configuration data is being transferred to the module from the ControlLogix controller. If the module's OK LED does not turn GREEN, verify that the module is inserted completely into the rack. If this does not cure the problem, contact ProSoft Technology Technical Support. ProSoft Technology, Inc.
  • Page 68: Troubleshooting

    User Manual IEC 61850 Server Communication Module Troubleshooting Use the following troubleshooting steps if you encounter problems when the module is powered up. If these steps do not resolve your problem, please contact ProSoft Technology Technical Support. Processor Errors Problem Description...
  • Page 69: Using The Diagnostics Menu In Prosoft Configuration Builder

    Tip: You can have a ProSoft Configuration Builder Diagnostics window open for more than one module at a time. To connect to the module, refer to Connecting Your PC to the Module. In the tree view in ProSoft Configuration Builder, right-click the MVI56E-61850S icon to open a shortcut menu. On the shortcut menu, choose D...
  • Page 70 Contents MVI56E-61850S ♦ ControlLogix Platform User Manual IEC 61850 Server Communication Module In the Ethernet field of the Connection Setup dialog box, enter the IP address that was assigned the module in Assigning a Permanent IP Address. In the Connection Setup...
  • Page 71 (using the grey cable) or directly between your computer and the module (using the red cable). If you are still not able to establish a connection, contact ProSoft Technology for assistance. ProSoft Technology, Inc.
  • Page 72 Contents MVI56E-61850S ♦ ControlLogix Platform User Manual IEC 61850 Server Communication Module 6.4.1 Monitoring Module Information Use the MODULE selection to view the module version, setup and health, and NIC status. Page 72 of 81 ProSoft Technology, Inc. September 4, 2014...
  • Page 73 MVI56E-61850S ♦ ControlLogix Platform Contents IEC 61850 Server Communication Module User Manual 6.4.2 Monitoring Backplane Information Use the BACKPLANE selection to view the configuration and backplane status information for the MVI56E-61850S module. ProSoft Technology, Inc. Page 73 of 81 September 4, 2014...
  • Page 74 Contents MVI56E-61850S ♦ ControlLogix Platform User Manual IEC 61850 Server Communication Module 6.4.3 Monitoring Base Configuration Information Use the 61850 SERVER - BASE CFG selection to view the 61850 server status information of the MVI56E-61850S module. Page 74 of 81 ProSoft Technology, Inc.
  • Page 75 IEC 61850 Server Communication Module User Manual 6.4.4 Monitoring Data Mappings Information Use the 61850 SERVER - DATA MAPPINGS selection to view the configured data mappings of each Data Object for the MVI56E-61850S module. ProSoft Technology, Inc. Page 75 of 81 September 4, 2014...
  • Page 76 MVI56E-61850S ♦ ControlLogix Platform User Manual IEC 61850 Server Communication Module 6.4.5 Monitoring Backplane Information Use the 61850 SERVER - REPORTS selection to view the 61850 protocol report configurations for the MVI56E-61850S module. Page 76 of 81 ProSoft Technology, Inc. September 4, 2014...
  • Page 77 MVI56E-61850S ♦ ControlLogix Platform Contents IEC 61850 Server Communication Module User Manual 6.4.6 Monitoring Flat Database Information Use the FLAT DATABASE selection to view the raw data values that currently populate the MVI56E-61850S module memory. ProSoft Technology, Inc. Page 77 of 81...
  • Page 78: Connect To The Module's Web Page

    Refer to Connecting Your PC to the Module for more information. In the Download files from PC to module dialog box, click B ROWSE EVICE In ProSoft Discovery Service, right-click the MVI56E-61850S icon and choose V ’ from the shortcut menu. MODULE S WEBPAGE This displays the module webpage.
  • Page 79 Contacting Technical Support ..............79  Warranty Information ................80 Contacting Technical Support ProSoft Technology, Inc. is committed to providing the most efficient and effective support possible. Before calling, please gather the following information to assist in expediting this process: Product Version Number...
  • Page 80 E-mail: brasil@prosoft-technology.com Languages spoken include: Portuguese, English Warranty Information For complete details regarding ProSoft Technology’s TERMS & CONDITIONS OF SALE, WARRANTY, SUPPORT, SERVICE AND RETURN MATERIAL AUTHORIZATION INSTRUCTIONS please see the documents on the Product DVD or go to www.prosoft-technology/legal Documentation is subject to change without notice.
  • Page 81 Monitoring Flat Database Information • 77 Monitoring Module Information • 72 MVI56E-61850S Configuration • 21 Index MVI56E-61850S Controller Tags • 49 MVI56E-61850S User-Defined Data Types • 49 MVI56E61850S.COMMAND • 51 MVI56E61850S.DATA • 50 MVI56E61850S.STATUS Tag • 52 61850S BR0x Dataset • 36 MVI56E61850S.UTIL Tag •...