Chapter 12 — Installing the circuit cards
LD 16 - Route Data Block
Prompt
Response
REQ
NEW
TYPE
RDB
CUST
0-99
ROUT
0-511
TKTP
DID
ICOG
ICT
ACOD
XX
MFC
YES, (NO)
CNTL
YES
TIMR
EOD 19968
ICF 0
GTI 128
NEDC
ETH
FEDC
ETH
PRDL
BSY
EOS
YES
Comments
Define a new Route Data Block
Enter customer number
Enter route number
Trunk type is Direct Inward Dial
Incoming only trunk
XX=trunk route access code
Multi-frequency compelled signaling
enabled, (disabled)
Change controls or timers
Set End of Dial timer to 19968 ms
Set Incoming Flash timer to 0 ms
Set Guard Timer Incoming to 128
Near end disconnect control from
either end
Far end disconnect control from either
end
Return Busy Tone on partial dial
time-out
Send End of Selection (number
received) signal
Option 11C Mini
Planning and Installation Guide