Terminal Block Requirements - Nortel Meridian 1 Planning And Installation Manual

Table of Contents

Advertisement

Page 230 of 590

Terminal block requirements

553-3021-209
Standard 1.00
Chapter 13 — Installing and connecting the cross-connect terminal
This chapter contains the following procedures:
Procedure 52 "Installing the BIX cross-connect terminal" on page 231
Procedure 53 "Installing the Reichle Masari cross-connect terminal
(Germany)" on page 232
Procedure 54 "Installing the Krone Test Jack Frame (UK)" on page 236
Procedure 55 "Connecting the cables" on page 239
The cross-connect terminal requires enough connecting blocks to terminate
the following wires:
for the NTAK09 circuit card, use the NTBK04 cable
for the NTAK10, NTAK79, and NTBK50 circuit cards, use the NTBK05
cable
up to five 25-pair cables from each chassis.
— Each slot that is equipped with a trunk or line circuit card requires a
cable.
– Connectors L1 through L6 on the back of the Main Chassis
correspond to card numbers 1 through 6 in the Main Chassis.
– Connectors L1 through L4 on the back of the Chassis Expander
correspond to card numbers 7 through 10 in the Chassis
Expander.
– Allow for additional cables at the cross-connect terminal if any
of the slots in the chassis are initially left empty.
— If the NTAK19EC 2-port SDI cable or the NTAK19FB 4-port SDI
cable are not used with the NTAK03 or NTAK02 cards, then you
require a 25-pair cable for each of these cards.
four conductors for the AUX cable from the Main Chassis
July 1999

Advertisement

Table of Contents
loading

This manual is also suitable for:

Option 11c mini

Table of Contents