NTAG04AA Central Office/Direct Inward Dial trunk card

Switch settings
The NTAG04AA card does not have any option switches. Configure all
settings in software.
Procedure 43
Installation of the NTAG04AA Central Office/Direct Inward Dial trunk
card
1
Insert the card into the selected card slot and lock it in position.
2
Connect the trunk units to the cross-connect terminal by tip and
ring leads (Refer to "Chapter 18 — Connecting the trunks" on
page 313).
3
Configure the card in software (LDs 16 and 14).
—————————— End of Procedure ——————————
LD 16 - Route Data Block
Prompt
REQ
TYPE
CUST
ROUT
TKTP
ICOG
ACOD
CNTL
TIMER
DTD
2DT
SCDT
Chapter 12 — Installing the circuit cards
Response
Comments
NEW
RDB
Define a new Route Data Block
0-99
Enter customer number
0-511
Enter route number
COT
Define the trunk type as central office
IAO
Incoming and Outgoing trunk
XXXXXXX
Trunk route access code
YES
Change a trunk timer
DSI 2048
Disconnect Supervision Timer =
2048 ms
GTI 512
Incoming Guard Timer = 512 ms
GTO 512
Outgoing Guard Timer = 512 ms
RGV 256
Ring Validation Timer = 256 ms
YES
Dial tone detector performed on this
route
YES
NO
Secondary dial tone is not used in
Holland