Nortel Meridian 1 Planning And Installation Manual page 226

Table of Contents

Advertisement

Page 206 of 590
553-3021-209
Standard 1.00
Chapter 12 — Installing the circuit cards
Direct Inward Dial trunk configuration
LD 16 - Route Data Block
Prompt
Response
REQ
NEW
TYPE
RDB
CUST
0-99
ROUT
0-511
TKTP
DID
ICOG
IAO
ACOD
XXXXXXX
CNTL
YES
TIMER
DSI 2048
GTI 512
GTO 512
RGV 256
DTD
YES
2DT
YES
SCDT
NO
XTDT
(0)-7
NEDC
ETH
FEDC
ETH
MR
PPM
PRDL
YES
EOS
YES
ACKW
YES
July 1999
Comments
Define a new Route Data Block
Enter customer number
Enter route number
Define trunk type as Direct Inward Dial
Incoming and Outgoing trunk
Trunk route access code
Change a trunk timer
Disconnect Supervision Timer
= 2048 ms
Incoming Guard Timer = 512 ms
Outgoing Guard Timer = 512 ms
Ring Validation Timer = 256 ms
Dial tone detector performed on this
route
Secondary dial tone is not used in
Holland
Extended tone detector table number
programmed in Overlay 97
(Enter 0 if the table has not already
been programmed in LD 97))
Near end disconnect control from
either end
Far end disconnect control from either
end
Buffered PPM signals counted on this
route
Partial timing equipped using EOD
End of Selection signal enabled
Seizure acknowledgment signal is
expected after seizure of a DID/DOD
trunk

Advertisement

Table of Contents
loading

This manual is also suitable for:

Option 11c mini

Table of Contents