Nortel Meridian 1 Planning And Installation Manual page 232

Table of Contents

Advertisement

Page 212 of 590
553-3021-209
Standard 1.00
Chapter 12 — Installing the circuit cards
LD 16 - Route Data Block
Prompt
Response
NEDC
ETH
FEDC
ETH
CDR
YES, (NO)
OAL
YES, (NO)
MR
PPM
Trunk Data Block
Use Overlay 14 to configure each of the trunk units on the NTCK24AA
Central Office trunk.
LD 14 - Route Data Block
Prompt
Response
REQ
NEW
TYPE
COT
TN
CC UU
CDEN
(8D)
XTRK
XCOT
(see note)
SIGL
LOP
PPID
07
BTID
07
CLS
DTN, (DIP)
Note: These prompts are required only for the first unit defined on each
NTCK24AA card.
July 1999
Comments
Near end disconnect control from
either end
Far end disconnect control from either
end
CDR trunk route. If Yes, answer OAL
and MR prompts.
CDR on outgoing calls
Buffered PPM signals counted on this
route
Comments
Define a new trunk unit
Central Office Trunk
Terminal number of the unit:
CC=card number
UU=unit number
Card density is 8D (default)
Type is IPE COT
Loop Start signaling
PPM country Identification
Busy Tone country identification
Digitone signaling, (Digipulse)