Nt5K96Nb/Nt5K02Nb Flexible Analog Line Card - Nortel Meridian 1 Planning And Installation Manual

Table of Contents

Advertisement

Page 172 of 590

NT5K96NB/NT5K02NB Flexible analog line card

553-3021-209
Standard 1.00
Chapter 12 — Installing the circuit cards
The NT5K02NB line card is available with message waiting, while the
NT5K96NB line card is equipped without message waiting.
Switch settings
There are no option switches on this card. Configure all settings in software.
Procedure 34
NT5K96NB / NT5K02NB Flexible analog line card installation
1
Insert the card in its allocated card slot.
2
Connect the line card units to the cross-connect terminal and
telephone by tip and ring leads.
3
Configure the telephone lines in software (LD 10).
—————————— End of Procedure ——————————
Self-test
The faceplates of the NT5K96NB and NT5K02NB cards have a red LED.
The LED lights when all of the assigned units on the circuit card are disabled.