Chapter 12 — Installing the circuit cards
Note: At times the system does not operate correctly if you install an
NTAK03 circuit card in a slot connected to telephones. Refer to "Chapter
13 — Installing and connecting the cross-connect terminal" on page 229
to connect an NTAK03 circuit card to the cross-connect terminal.
Procedure 15
NTAK03 card installation
1
Insert the card in its assigned slot.
You can insert the NTAK03 TDS/DTR card into card slots 1 to 3 of the
Main Chassis.
2
Connect an NTAK19EC cable (or an NE-A25-B cable) from the
corresponding connector at the back of the chassis. If you are
using an NE-A25-B cable, terminate this cable at the
cross-connect terminal. Because the NTAK19EC cable is
equipped with connectors, it does have to be terminated at the
cross-connect terminal.
—————————— End of Procedure ——————————